Online Catalogue
Select the item of interest below
| MODEL / SERIES | ITEM DESCRIPTION | AVAILABILITY | SPEC | ADDITIONAL DATA |
| High Power | ||||
| Model 98952-A | Digital High-Power Wattmeter includes two 10-foot cables and AC adapter. Requires appropriate single socket line section and element. Uses 5/10/25 scale Digital Elements. | TBD | details | |
| Model 98954-A | Digital High-Power Wattmeter includes FWD/RFL switch, four 10-foot cables and AC adapter. Requires appropriate dual socket line section and elements. Uses 5/10/25 scale Digital Elements. | TBD | details | |
| Model 98958-A | Digital High-Power Wattmeter includes two 10-foot cables and AC adapter. Requires appropriate single socket line section and element. 15/30/60 Scales. | TBD | details | |
| Model 98959-A | Digital High-Power Wattmeter includes FWD/RFL switch, four 10-foot cables and AC adapter. Requires appropriate dual socket line section and elements. 15/30/60 Scales. | TBD | details | |
| Model 811xx | Rigid line directional RF Wattmeters for 1 5/8 line size. Several different models are available with either 5/10/25 scales or 15/30/60 scales. | TBD | details | |
| Model 813xx | Rigid line directional RF Wattmeters for 3 1/8 line size. Several different models are available with either 5/10/25 scales or 15/30/60 scales. | TBD | details | |
| Model 814xx | Rigid line directional RF Wattmeters for 4 1/16 line size. Several different models are available with either 5/10/25 scales or 15/30/60 scales. | TBD | details | |
| Model 816xx | Rigid line directional RF Wattmeters for 6 1/8 line size. Several different models are available with either 5/10/25 scales or 15/30/60 scales. | TBD | details | |
| Broadband | ||||
| Model 81050 | With non-removable Broadband Element allowing full-scale power measurement on any one of 5 selectable ranges of 5, 15, 50, 150, and 500 watts across a frequency range of 25 to 1000 MHz. | TBD | details | |
| Model 81060 | With non-removable Broadband Element allow full-scale power measurement on any one of 5 selectable ranges of 15, 50, 150, 500, and 1500 watts across a frequency range of 25 to 1000 MHz. | TBD | details | |
| Average Reading | ||||
| Model 81001-A | Power range 100 mW to 10 kW with A/B switchable DC input. | TBD | details | |
| Peak/Average Reading | ||||
| Model 83000-A | Peak power measuring capability between 2 to 2300 MHz and from 100 mW to 10 kW. | TBD | details | |
| Model 83060 | Power Ranges 15, 50, 150, 500 and 1500 watts full scale (500 watts maximum from 800 to 1000 MHz) | TBD | details | |
| Model 83550 | Multi-function Wattmeter, with digital display, internal line section, Quick Match connectors, and a set of frequency/power discriminating plug-in elements form an analytical RF power measuring system. Capabilities include measurement of peak or average power, absolute or relative power, along with VSWR and return loss. | TBD | details | |
| Relative Strength | ||||
| Model 7601 | For measuring the relative strengths of radiating fields of patterns from a transmitting antenna system, making relative RF power measurements, or peaking and adjusting fixed or portable transceivers and antennas. | TBD | details | |
| Panel mount | ||||
| Model 81002-A | 19" Panel with single meter, FWD/RFL switch and 7/8" Dual Socket Line Section. | TBD | details | |
| Model 81003-A | 19" Panel with single meter and 7/8" Dual Socket Line Section. | TBD | details | |
| Model 81006-A | 19" Panel with dual meter and 7/8" Dual Socket Line Section. | TBD | details | |
| Model 81017-A | 19" Panel with single meter and 7/8" Single Socket Line Section. Has the added feature of an A/B switchable DC input providing the option of single meter measurement of several power sources | TBD | details | |
| Model 81004-A | 19" Panel with single meter (5/10/25 scale) and FWD/RFL switch for use with Dual Socket Line Sections | TBD | details | |
| Model 81005-A | 19" Panel with dual meters ( 5/10/25 scale) for use with Dual Socket Line Sections. | TBD | details | |
| Model 81007-A | 19" Panel with dual meters ( 5/10/25 scale) and 2P5T switch for use with Dual Socket Line Sections. Housing with mounting feet monitors up to five transmitters with additional cables. | TBD | details | |
| Model 81007-B | Panel mount version of 81007-A | TBD | details | |
| Model 81008-A | 19" Panel with single meter ( 5/10/25 scale) for use with Single Socket Line Sections. | TBD | details | |
| Model 81014-A | 19" Panel with single meter (15/30/60 scale) and FWD/RFL switch for use with Dual Socket Line Sections. | TBD | details | |
| Model 81015-A | 19" Panel with dual meters (15/30/60 scale) for use with Dual Socket Line Sections. | TBD | details | |
| Model 81016-A | 19" Panel with single meter (15/30/60 scale) for use with Single Socket Line Sections | TBD | details | |
| Monitor/Alarm systems | ||||
| Model 91090/91091 | An alarm system designed for the accurate measurement of complex RF Waveforms such as CDMA (Code Division Multiple Access), DAB (Digital Audio Broadcast), DTV (Digital TV) and HDTV (High Definition TV), as well as CW, AM and FM. | TBD | details | |
| 81070 / 81080 sereis | Wattchman Monitor/Alarm systems measure forward and reflected RF
power simultaneously in 50-Ohm coaxial cables and transmission
lines.Compatible with entire series of 7/8" through 6-1/8" Line
Sections, accepts plug-in elements from 5 watts to 100 kW full scale
from 0.45 MHz to 2300 MHz.One or both meters may incorporate a front
panel adjustable set point which controls the trip point of the
alarm. The 81070 Series has 5/10/25 scales and the 81080 Series has
15/30/60 scales. |
TBD | details | |
| 81090 / 81091 sereis | Wattchman Monitor/Alarm measures forward and reflected RF power simultaneously in 50-Ohm coaxial cables and transmission lines.Compatible with entire series of 7/8" through 6-1/8" Line Sections, accepts plug-in elementsfrom 5 watts to 100 kW full scale from 0.45 MHz to 2300 MHz.Similar in appearance to 81070 & 81080 Series. Both models feature forward and reflected trip adjustments,a built in DC amplifier and 110/220 VAC input switch. Model 81090 has standard 5/10/25 scales and Model 81091 has 15/30/60 scales. | TBD | details | |
| ACCESSORIES | ||||
| Plug in elements | ||||
| 92000 series | Digital Broadcast Elements for 1 5/8 to 6 1/8, frequency bands from 54-806MHz and power ratings between 100W - 100kW | TBD | details | |
| 82000 series for 7/8" line size | Includes high power, low power and milliwatt variants | details | ||
| 82100 series for 1 5/8" line size | Power rating to 25kW, Frequency 2MHz - 1000MHz (5/10/25 & 15/30/60 Scales) | details | ||
| 82300 series for 3 1/8" line size | Power rating to 60kW, Frequency 2MHz - 1000MHz (5/10/25 & 15/30/60 Scales) | details | ||
| 82400 series for 4 1/16" line size | Power rating to 100kW, Frequency 2MHz - 1000MHz (5/10/25 & 15/30/60 Scales) | details | ||
| 82600 sereis for 6 1/8" line size | Power rating to 100kW, Frequency 2MHz - 1000MHz (5/10/25 & 15/30/60 Scales) | details | ||
| Line Sections | ||||
| 7/8" line sections | Several different models are available in either single socket or dual socket with a wide variety of connector options. Dual socket line sections allow both forward and reflected power measurements using only one line section and a meter with a FWD/RFL switch, or a panel mount configuration with 2 meters. | TBD | details | |
| 1 5/8" line sections | Several different models are available in either single socket or dual socket with Flanged, Unflanged Flush, or Unflanged Recessed connections. Dual socket line sections allow both forward and reflected power measurements using only one line section and a meter with a FWD/RFL switch, or a panel mount configuration with 2 meters. | TBD | details | |
| 3 1/8" line sections | Several different models are available in either single socket or dual socket with Flanged,Unflanged Flush, or Unflanged Recessed connections. Dual socket line sections allow both forward and reflected power measurements using only one line section and a meter with a FWD/RFL switch, or a panel mount configuration with 2 meters. | TBD | details | |
| 4 1/16" line sections | Several different models are available in either single socket or dual socket with Flanged, Unflanged Flush, or Unflanged Recessed connections. Dual socket line sections allow both forward and reflected power measurements using only one line section and a meter with a FWD/RFL switch, or a panel mount configuration with 2 meters. | TBD | details | |
| 6 1/8" line sections | Several different models are available in either single socket or dual socket with Flanged, Unflanged Flush, or Unflanged Recessed connections. Dual socket line sections allow both forward and reflected power measurements using only one line section and a meter with a FWD/RFL switch, or a panel mount configuration with 2 meters. | TBD | details | |
| Power Sensors | ||||
| RF Power sensors | Freq range 2 - 1000MHz & wiide range of Power FWD/RFL ratios. All models are designed to drive a 30μA, 1400-Ohm meter, or provide approximately 100 millivolts across a 5K load. Directivity is typically 25 dB minimum. Mainline connectors are type N Female standard. | TBD | details | |
| Adjustable Tap offs | ||||
| 7990 | 500 W 2-1000 MHz 15 - 70 dB UHF Male/Female | TBD | details | |
| 7991 | 500 W 2-1000 MHz 15 - 70 dB BNC Female/Female | TBD | details | |
| 7992 | 500 W 2-1000 MHz 15 - 70 dB N Male/Female | TBD | details | |
| 7993 | 500 W 2-1000 MHz 15 - 70 dB N Female/Female | TBD | details | |
| 7995 | 500 W 2-1000 MHz 15 - 70 dB UHF Female/Female | TBD | details | |
| Signal Samplers | ||||
| 7998 | 2 MHz to 1000 MHz, N Female/N Female N Male/N Female UHF Female/UHF Female UHF Male/UHF Female QM Interface | TBD | details | |
| 7999 | 2 MHz to 1000 MHz, N Male/N Female UHF Female/UHF Female UHF Male/UHF Female QM Interface | TBD | details | |
| Plugin X-Tractors | ||||
| Adjustable | ||||
| 87004 | 2 MHz to 1000 MHz, BNC Female, 7/8" line, 43 +/- 8 dB | TBD | details | |
| 87005 | 2 MHz to 1000 MHz, BNC Female, 7/8" line, 45 +/- 8 dB | TBD | details | |
| 87021 | 2 MHz to 1000 MHz, BNC Female, 1-5/8" line, 49 +/- 8 dB | TBD | details | |
| 87031 | 2 MHz to 1000 MHz, BNC Female, 3-1/8" line, 56 +/- 8 dB | TBD | details | |
| Directional | ||||
| 87014S | 7/8" 1000 W 37.5 +/- .75 dB 54 to 90 MHz | TBD | details | |
| 87015 | 7/8" 1000 W 50 +/- 1 dB 50 to 500 MHz | TBD | details | |
| 87016 | 7/8" 1000 W 37.5 +/- .75 dB 174 to 230 MHz | TBD | details | |
| 87024 | 1-5/8" 1000 W 40 +/- 1 dB 50 to 500 MHz | TBD | details | |
| 87024H | 1-5/8" 5000 W 40 +/- 1 dB 50 to 500 MHz | TBD | details | |
| 87025 | 1-5/8" 10 kW 50 +/- 1 dB 50 to 500 MHz | TBD | details | |
| 87026 | 1-5/8" 2500 W 45 +/- 1 dB 400 to 800 MHz | TBD | details | |
| 87027 | 1-5/8" 5000 W 50 +/- 1 dB 400 to 800 MHz | TBD | details | |
| 87035 | 3-1/8" 10 kW 50 +/- 1 dB 50 to 500 MHz | TBD | details | |
| 87035H | 3-1/8" 35 kW 50 +/- 1 dB 50 to 500 MHz | TBD | details | |
| 87036 | 3-1/8" 100 kW 60 +/- 1 dB 50 to 500 MHz | TBD | details | |
| 87038 | 3-1/8" 5000 W 50 +/- 1 dB 400 to 800 MHz | TBD | details | |
| 87039 | 3-1/8" 10 kW 70 +/- 1 dB 400 to 800 MHz | TBD | details | |
| 87046 | 4-1/16" 50 kW 60 +/- 1 dB 50 to 500 MHz | TBD | details | |
| 87066 | 6-1/8" 50 kW 60 +/- 1 dB 50 to 500 MHz | TBD | details |